The core of maintaining a ledger is three items: cycle, project, and judgment criteria. If one item is missing, it will become a formality.

  • Vistas: ...
  • Tempo de liberação: 2026-11-16

The core of maintaining a ledger is three items: cycle, project, and judgment criteria. If one item is missing, it will become a formality.

1、 Periodic grading

Daily shift inspection, every 500 module inspection, and every 5000 module deep inspection are three levels.

The daily inspection includes water temperature, air pressure, and spraying status, which takes about 15 minutes.

Cracking and polishing every 5000 cycles are key actions to extend lifespan.

2、 Checklist of inspection items

The four basic items are cavity cracks, unobstructed exhaust slots, ejector pin action, and cooling flow rate.

It is recommended to use dye penetration for crack inspection, with a depth of 0.5 millimeters as the warning line.

If the carbon accumulation in the exhaust groove exceeds 0.05 millimeters, it needs to be cleaned.

3、 Judgment and disposal

Cracks with a depth of 1 to 1.5 millimeters can be repaired by polishing, and those exceeding 1.5 millimeters will be evaluated for mold replacement.

The top pin is stuck with a travel difference of more than 0.1 millimeters and needs to be disassembled for inspection and lubrication.

If the flow rate drops by more than 20%, it indicates scale or blockage.

4、 Record and Trace

The ledger should record the module number, temperature, pressure, maintenance items, and responsible person.

It is recommended to retain data for no less than two years to facilitate quality traceability.

Xinfeng provides ledger templates and judgment threshold tables along with the mold.

5、 Effect evaluation

The average lifespan of standardized maintenance molds is about 25% higher than those without records.

Unplanned downtime can be reduced by about 30%.

Industry observations show that factories with high ledger execution rates have lower mold repair costs.

Conclusion and Outlook

Maintenance is not about repairing once it's broken, but rather eliminating deterioration on a periodic basis.

The solidification of cycle, list, and judgment improves both lifespan and downtime.

Extension: Three supporting facilities for ledger implementation

Package 1: Write the inspection items in the shift handover form to avoid verbal communication.

Matching 2: Set judgment thresholds for each item to avoid vague conclusions that look okay.

Package 3: Set up an abnormal upgrade path and report within 24 hours of exceeding the threshold.

When the three supporting items are missing, the ledger often becomes a signed form.

Xinfeng provides printable ledger templates with molds, including threshold and upgrade columns.

The ledger will be reviewed once after three months of execution, and the rules will be more in line with reality.

Addendum: Five improvements in ledger execution

The first month execution rate of the ledger is usually less than half, and a dedicated person needs to conduct weekly spot checks.

When the number of inspection items exceeds 15, the execution rate significantly decreases. It is recommended to compress it to less than 10 items.

The threshold for judgment needs to be set according to the device's capability, and if it is too high, it will make the records become mere formalities.

Monthly summary of defects and maintenance records, patterns are more valuable than individual data.

Ledger data can be used for spare parts planning, and the proportion of temporary purchases usually decreases by about 30%.

Addendum 2: Three handovers for line shutdown and resumption of production

If the downtime exceeds 7 days, a rust prevention treatment should be carried out, and the mold cavity should be covered with oil for protection.

Before resuming production, conduct a trial run with an empty loop, and any abnormal movements can be detected before the first piece.

It is recommended to conduct a full-size inspection on the first piece for resuming production. If the mold temperature is not stable, there may be a significant deviation in the first piece.

Addendum 3: Two Requirements for Maintenance Personnel

Inspectors need to be able to identify cracks below 0.5 millimeters, as insufficient training may result in missed detections.

During handover, verbal instructions must be consistent with the ledger. In case of any inconsistency, the ledger shall prevail.

FAQ

How many levels of maintenance are there? Daily, every 500 cycles, every 5000 cycles, three levels.

How long does the daily check last? About 15 minutes.

What is the crack warning line? Depth of 0.5 millimeters.

How much carbon buildup in the exhaust duct needs to be cleaned? Exceeding 0.05 millimeters.

How deep can the crack be repaired? 1 to 1.5 millimeters can be polished and repaired.

How long should the ledger be kept? Suggest no less than two years.

How much longer can standardized maintenance extend lifespan? About 25%.

Sítio Web Deste artigo: https://pt.zj-xinfeng.com/case/1505.html

Get a Custom Product Proposal Online

Please fill out the form below to receive this for free.

Global Hotline:

+86-15356852630,13967513266

Moldes para fundição por baixa pressão (LPDC) 
Moldes para fundição por gravidade 
Moldes para fundição por contrapressão (CPC) 
Moldes para fundição de peças estruturais
Molde para fundição de cubos de roda de motocicleta
Molde para fundição por pressão diferencial de cubos de roda
Molde para fundição por gravidade de cubos de roda
Molde para fundição por baixa pressão de cubos de roda

MOLDES PARA JANTES AUTOMÓVEIS 
PEÇAS ESTRUTURAIS AUTOMÓVEIS 
OUTROS COMPONENTES DE FUNDIDOS DE ALUMÍNIO

NOTÍCIAS DA EMPRESA
NOTÍCIAS DO SETOR
BLOG TÉCNICO
PERGUNTAS FREQUENTES

PERFIL DA EMPRESA
ESTRUTURA ORGANIZACIONAL
HISTÓRICO DE DESENVOLVIMENTO
PROPRIEDADE INTELECTUAL
ESPÍRITO DE EQUIPA PARCEIRO

Copyright © Zhejiang Xinfeng Machinery Co., Ltd. All Rights Reserved.