The core of waterway design is spacing, flow rate, and temperature difference. Spacing determines uniformity, while flow rate determines rhythm.

  • Vistas: ...
  • Tempo de liberação: 2026-11-16

The core of waterway design is spacing, flow rate, and temperature difference. Spacing determines uniformity, while flow rate determines rhythm.

1、 Spacing divided by wall thickness

The center distance of the waterway in thin-walled areas is taken as 20 to 25 millimeters, while in thick walled areas it is taken as 30 to 35 millimeters.

When the spacing exceeds 40 millimeters, the temperature difference on the mold surface often increases to over 15 degrees Celsius.

The distance between the waterway and the surface of the mold cavity is set at 25 to 35 millimeters, and being too close can easily cause local supercooling.

2、 Flow rate and pressure drop

It is recommended that the flow rate of a single waterway should not be less than 8 liters per minute, and the pressure drop should be controlled at 0.15 megapascals.

Insufficient flow will prolong the cooling time by about 20% and decrease the beat accordingly.

When multiple points are connected in parallel, flow balancing is required, and branch deviation should be controlled within 10%.

3、 Temperature difference control

The temperature difference of the mold surface should be controlled within plus or minus 5 to 8 degrees Celsius. Exceeding this range will result in uneven hardness and deformation.

The inlet temperature is usually set at 25 to 30 degrees Celsius, and the outlet temperature rise is controlled within 5 degrees Celsius.

Xinfeng's mold adopts zone independent temperature control, and the flow rate in the key hot zone can be adjusted separately.

4、 Structure and Maintenance

The inner wall of the waterway needs to be treated with rust prevention. If it is stopped for a long time, it should be emptied and dried.

A scale thickness exceeding 0.2 millimeters will significantly reduce heat transfer efficiency and requires regular cleaning.

It is recommended to check the flow rate and temperature difference once every quarter to form a maintenance ledger.

5、 Verification method

Measure the temperature field of the mold surface using infrared or thermocouple, with a grid spacing of 50 millimeters.

When the measured temperature difference deviates from the design by more than 30%, the direction of the waterway should be rechecked.

Industry data shows that after optimizing the waterway, the average cooling time per unit has been reduced by about 18%.

Conclusion and Outlook

The denser the waterway, the better. The density should match the wall thickness and heat nodes.

First, conduct temperature field measurements, and then adjust the spacing and flow rate to improve both rhythm and quality.

Extension: Three Hard Constraints in Waterway Design

If the pressure difference of each branch of the water separator exceeds 0.05 megapascals, the remote flow will be significantly insufficient.

The turning radius of the waterway is too small, resulting in an increase in local pressure drop, and the actual flow rate is about 20% lower than the design value.

The parallelism deviation between the pipeline and the mold cavity exceeds 2 millimeters, and the actual spacing may deviate from the design.

If the diameter of the inlet and outlet joint is smaller than the design value, it will become a flow bottleneck for the entire circuit.

When the three constraints are not met, even the densest arrangement cannot suppress the temperature difference.

Annotate constraints on the design drawings to prevent deformation in the machining and assembly processes.

Addendum: Three reminders for waterway maintenance

Corrosion of the inner wall of the waterway can reduce heat transfer efficiency by about 15%. It is recommended to conduct an endoscopic examination every six months.

The mold with partitioned temperature control needs to be equipped with independent regulating valves, and sharing valves will make the partitioning meaningless.

Long term disuse should be drained and dried, and the cost of cleaning after residual water scaling may double.

Addendum 2: Two inspections of the cooling system

Measure the flow rate of each branch every quarter and record it. If the attenuation exceeds 20%, it indicates blockage or scaling.

If the mold is not used for more than two weeks, it needs to be emptied and dried, otherwise residual water will form sediment in the waterway.

FAQ

What is the spacing between waterways? Thin wall 20 to 25 millimeters, thick wall 30 to 35 millimeters.

How far away is the waterway from the mold cavity? 25 to 35 millimeters is more suitable.

What is the requirement for a single traffic? Suggest not less than 8 liters per minute.

How much is the temperature difference controlled on the mold surface? Within plus or minus 5 to 8 degrees Celsius.

What is the inlet water temperature? Usually set at 25 to 30 degrees Celsius.

How thick is scale affecting heat transfer? Beyond 0.2 millimeters, there is a significant decrease.

How often is the test conducted? Suggest measuring flow rate and temperature difference every quarter.

Design of exhaust slots for aluminum alloy casting molds: five common misconceptions

Sítio Web Deste artigo: https://pt.zj-xinfeng.com/case/1482.html

Get a Custom Product Proposal Online

Please fill out the form below to receive this for free.

Global Hotline:

+86-15356852630,13967513266

Moldes para fundição por baixa pressão (LPDC) 
Moldes para fundição por gravidade 
Moldes para fundição por contrapressão (CPC) 
Moldes para fundição de peças estruturais
Molde para fundição de cubos de roda de motocicleta
Molde para fundição por pressão diferencial de cubos de roda
Molde para fundição por gravidade de cubos de roda
Molde para fundição por baixa pressão de cubos de roda

MOLDES PARA JANTES AUTOMÓVEIS 
PEÇAS ESTRUTURAIS AUTOMÓVEIS 
OUTROS COMPONENTES DE FUNDIDOS DE ALUMÍNIO

NOTÍCIAS DA EMPRESA
NOTÍCIAS DO SETOR
BLOG TÉCNICO
PERGUNTAS FREQUENTES

PERFIL DA EMPRESA
ESTRUTURA ORGANIZACIONAL
HISTÓRICO DE DESENVOLVIMENTO
PROPRIEDADE INTELECTUAL
ESPÍRITO DE EQUIPA PARCEIRO

Copyright © Zhejiang Xinfeng Machinery Co., Ltd. All Rights Reserved.